Note: End of support for Tekran 2537A and 2537B (click on the link)
(Link to slideshow of the Tekran 2537X)
The Tekran® 2537X performs continuous and long-term, unattended, unsupervised mercury mercury gas analysis with unparalleled precision, sensitivity and reliability. The Tekran® 2537X is easy to set up, use and maintain, and has long been recognized for its stable performance in adverse conditions. Our instruments were installed in both polar regions, on ocean research ships and hundreds of other locations. As proof of the longevity of our products, the first Tekran® 2537X analyzers produced are still working perfectly and producing quality data after more than 15 years of continuous operation.
Although Tekran® 2537X it is normally used for continuous ambient air monitoring, other applications are easily achievable. For example, by continuously measuring the input and output of a flow chamber, the exceptional sensitivity of the 2537X can be used to determine differential emission and deposition rates on the surface. The 2537X is often used with the 1130 and 1135 models to continuously measure the speciation of atmospheric mercury. The 2537X has also been applied in the study and monitoring of mercury control technologies, dissolved gas mercury, surface flow by gradient techniques, indoor air, feather chemistry, free troposphere air, and impacts of point sources, including others. In cases where higher atmospheric concentrations are expected, Tekran® 2537X can be purchased in an alternative configuration to extend the upper range of the analyzer. This is useful for industrial monitoring projects and remediation of locations where mercury concentrations are expected to far exceed typical ambient air concentrations.
For more information and a complete list of specifications and uses, download the datasheet.
The ambient air analysis instruments of Tekran® have used in all oceans and continents, including in Antarctica. The Mercury Monitor in the ambient air model 2537 from Tekran® was the first product developed by the company e to be continued being a driving force for innovation. The 2537 model is the only available analyzer capable of performing atmospheric mercury speciation in an automated, continuous and unattended way. Our instruments produce accurate, high-resolution data that continue to improve the understanding of the mercury cycle in the environment. Tekran® ambient air analyzers were chosen by monitoring networks in the USA (NADP-AMNet), Canada (CAPMoN), Europe (EMEP) and in many other countries such as South Korea, China, Germany, Poland and South Africa, among others. As proof of our excellence, our analyzers set the standard for ambient air monitoring, with hundreds of facilities around the world.
Capable of continuous, long-lasting and unsupervised operation, the ambient air analyzer Tekran® 2537X it has become the world standard for mercury measurement in the ambient air. The combination of our patented double-gold dual cartridges and the ultrastable CVAFS detector provide unparalleled accuracy, sensitivity and reliability. o Tekran® 2537X opened a wide range of applications that were published in peer reviewed scientific journals. The only limit is the scientist's imagination.
A Tekran® it offers the only system in the world capable of carrying out automated determinations of mercury speciation. o Tekran® 1130 it was designed to seamlessly integrate with the Tekran® analyzer 2537. With a control module and a collection module (denuder), the Tekran® 1130 allows the separation and pre-concentration of oxidized mercury gaseous species (GOM) in an annular denuder. Using a patented thermal desorption process, the GOM is converted to elemental mercury for introduction on the Tekran® analyzer 2537. O Tekran® 1130 allows you to determine GOM concentrations as low as 2 picograms/m³ ( 0,2 ppq).
O Tekran® 1135 adds particle-bound mercury (PBM) determination to the capabilities of the 2537-1130 system. o Tekran® 1135 perfectly integrates with the denudator module Tekran® 1130 – No additional assembly is required. The PBM is captured in a regenerable particle filter and heat-decomposed elemental mercury for introduction to the Tekran® analyzer. 2537. O Tekran® 1135 allows you to determine PBM concentrations as low as 2 picograms/m³ ( 0,2 ppq).
The mercury vapor calibration unit Tekran® Model 2505 is designed to provide an external traceable pattern for auditing the internal mercury calibration source Tekran® 2537. However, the model 2505 offers an accurate and reproducible means of injecting a known amount of elementary mercury vapor into any analytical system. As the concentration of saturated mercury vapor is a well-known function of temperature, it is enough to know the exact volume injected and the temperature of the saturated steam to determine the mass of mercury injected.
The oxidized mercury speciation unit model 1130 from Tekran® enlarges the Vapor analyzer capabilities Mercury model 2537 to simultaneously monitor oxidized mercury and elemental mercury species (GOM, also known as RGM) in ambient air. The patented Model 1130 is the only system in the world capable of performing automated mercury speciation in the air. The 1130 model is an indispensable tool for research and monitoring programs, being recognized for its robustness, reliability and performance in extreme environments. The instrument's status and performance are continuously monitored through the Tekran® DataCom software , providing the operator with continuous quality assurance results.
The measurement of gaseous mercury (GOM) with Tekran® Model 1130 is the important link that connects the deposition of atmospheric mercury to sensitive aquatic ecosystems. GOM emissions from point sources, in situ production and transport can result in a local increase in mercury deposition. Therefore, the atmospheric speciation of mercury is of particular interest close to industrial sources. More than 100 peer-reviewed articles were published with data generated by Tekran® Model 1130 in field locations around the world. The mercury atmospheric speciation system Tekran® 2537-1130-1135 was chosen by networks around the world, including the Canadian-CAPMoN, NADP AMNet, EU EMEP, Korea-NIER, Chinese Academy of Sciences and others.
Most atmospheric mercury is present in the elementary form, but the differentiation is important due to the greater local impact of the reactive (ionic) forms. The 1130 model offers a supplementary pump system to minimize sample collection periods and produce mercury free air for use during analytical cycles.
For more information and a complete list of specifications and uses, download the datasheet.