NanoQ is wide wavelength microvolume spectrophotometer with modern design and user convenience UI. It supplies extremely fast and easy quantitative analysis of nucleic acid and protein by UV-Vis absorption spectrophotometry. It provides microvolume sample measuring mode and cuvette measuring mode so can measure wide range of concentration. You can easily set over 20 measuring modes.
| Product Name | OPTIZEN NanoQ Plus | OPTIZEN NanoQ |
|---|---|---|
| Photometrics System | Microvolume Spectrophotometer | |
| Light Source(s) | Xenon flash lamp | |
| Lifetime | Up to 10 years | |
| Detector | CMOS linear image sensor (2048 pixels) | |
| Spectral Bandwidth | 1.0 nm (FWHM at Hg 253.7 nm) | |
| Wavelength Range | 190 - 850 nm | |
| Wavelength Display (setting) | 1 nm | |
| Wavelength Accuracy | ± 1 nm | |
| Microvolume | ||
| Minimum Sample Volume | 1 μL | |
| Photometric Range | 0.04 - 550 A (10mm equivalent) | |
| Detection Limit (Microvolume) | 2 ng/μL (dsDNA) 0.06 mg/mL (BSA) 0.003 mg/mL (IgG) |
|
| Maximum Concentration | 27,500 ng/μL (dsDNA), 400 mg/mL (BSA) | |
| Cuvette | ||
| Photometric Range | 0 - 2 A | - |
| Detection Limit | 0.2 ng/μL (dsDNA) 0.006 mg/mL (BSA) 0.0003 mg/mL (IgG) |
- |
| Center Height (Z-height) | 8.5 mm | - |
| Absorbance Precision | 0.002 A (0.5 mm path) or 1% | |
| Absorbance Accuracy | 3% (at 0.97A at 302 nm) | |
| Measurement Time | < 8 seconds | |
| Software Compatibility | Windows® 7 and 10 | |
| Touchscreen | Multipoint capacitive touch | |
| CPU | Octa Core ARM® CortexTM-A53 Processor | |
| Storage | 32 GB Internal Storage | |
| Glove Compatibility | Compatible with lab gloves | |
| Connectivity | 4 x USB ports, Ethernet, and RS-232 | |
| Display | 7-inch, 1280 x 800 HD color display | |
| Operating System (OS) | AndroidTM | |
| Footprint (W*D) | 216*290 mm | |
| Weight | 3.0 kg | |
* The contents of this document may be changed without notice.
There is no need for a user manual since it provides a simple and intuitive user environment. The designated factor is set as the default value for each mode, and the input mode is provided to allow the users to set a factor value which is different from the default. Users can specify the factor ppropriate for the user preference, the lab environment, and the type of protein.
| Measurement menu configuration | ||
| Menu | Factor | |
| Nucleic Acid (ng-㎝/㎕) |
dsDNA | 50 |
| ssDNA | 33 | |
| RNA | 40 | |
| miRNA | 33 | |
| Custom | Input | |
| Protein (g-㎝/㎕) |
BSA | 1.5 |
| SA | 1.49, 1.72 | |
| IgG | 0.71, 0.74 | |
| IgE Human | 0.65 | |
| Lysozyme | 0.38 | |
| OD1 | 1 | |
| OD600 | OD600 | 1 |