Sterilization and autoclaves
Autoclaves and decontamination systems for instruments and waste.
Technical portfolio from −196 °C to +8 °C: Ultrafreezers, cryogenics, scientific refrigerators, vaccine solutions and blood bank, cell culture, biosecurity and analytical instrumentation — with international certification and intelligent monitoring.
Technology for research, health and diagnosis
We have gathered in a single portfolio the essential equipment for hospitals, research laboratories, pharmaceutical industry, biobanks, blood centers and immunization centers. Each line is designed for thermal uniformity, energy efficiency and traceability — protecting samples and high value inputs.
CE · UL · ENERGY STARUltra-low temperature · UltraFreeze line −86 °C
Ultra-low temperature freezers (ULT) for long-term preservation of biological samples, DNA/RNA, cells, vaccines and sensitive reagents. Cascading cooling systems, Stirling technology and frequency inverters ensure thermal stability and energy savings.
| Temperature range | −40 °C to −86 °C, adjust in steps of 1 °C |
|---|---|
| Capacity | from 15 L (mini/bench) to 960 L (400+ racks) |
| Refrigeration | Two-stage cascade, Stirling or TwinCool inverter |
| Isolation | VIP (vacuum panels) + high density polyurethane |
| Efficiency | Ultraecho/low-energy versions with reduced consumption |
| Security | CO₂/LN₂ backup optional, door with closure and access record |
CE · UL · ENERGY STARBiomedical freeze · BioFreeze line −25/−40/−60 °C
Laboratory Freezers for plasma storage, reagents, diagnostic kits and samples that require intermediate freezing ranges. Compressors with intelligent frequency inverter reduce consumption and noise while maintaining thermal uniformity throughout the camera.
| Temperature range | −10 °C to −60 °C according to the line |
|---|---|
| Capacity | 92 L a 1.280 L |
| Settings | vertical, horizontal (chest) and double door |
| Organization | 3 to 12 drawers / adjustable shelves |
| Cooling | forced or direct air; Optional Smart Inverter |
| Feeding | 100–230 V, 50/60 Hz |
CE · UL · ATEXConservation 2–8 °C · PharmaCold line 2–8 °C
Precision refrigerators for medicines, reagents, clinical samples and chromatography. Microprocessor control maintains 2–8 °C with minimal oscillation, forced air circulation and visual and audible alarm system. Anti-explosion versions (Spark-Free / ATEX) for flammable solvents.
| Temperature range | 2 °C to 8 °C (cooling); −10 to −40 °C in the combined versions |
|---|---|
| Capacity | 68 L a 1.378 L |
| Doors | Single/double or solid glass, with closure |
| Uniformity | Forced air circulation + calibrable sensor |
| Special versions | Spark-Free ATEX, Chromatography, RFID, Combined Refrigerator+Freezer |
| Monitoring | LCD/LED display, open door alarm and alarm |
CE · UL · MDRHemotherapy · HemoSafe Line 4 °C
Safe conservation of blood bags and blood components at 4 °C ±1 °C, with rapid temperature recovery after door opening and continuous monitoring. Plasma Freezers from −30 °C to −40 °C complete the management of the transfusion cycle.
| Temperature | 4 °C ±1 °C (blood) · −30/−40 °C (Plasma) |
|---|---|
| Capacity | 106 L a 1.369 L |
| Storage | 54 to 624 bags (400–450 ml); 2 to 48 drawers |
| Monitoring | Temperature recorder 7 days, multilevel alarms |
| Versions | Touchscreen, vehicle, automated self-service distribution |
| Feeding | 115 V/60 Hz ou 220–240 V/50–60 Hz |
WHO PQS · CEImmunization · VaccineChain Line
Cold chain equipment for immunobiologicals, including ice-lined coolers (ILR), freezers for ice coils and direct-drive solar versions for regions without a stable power grid. Long thermal autonomy (Holdover) protects doses in power outages.
| Temperature | 2 °C to 8 °C (ILR) · −15 °C to −25 °C (Freezer) |
|---|---|
| Capacity | 22.5 L to 286 L (0.8 to 10.1 ft³) |
| Autonomy (Holdover) | more than 4 h to 7 h until −5 °C without power |
| Energy | 220–240 V 50/60 Hz and direct-drive solar (off-grid) |
| Monitoring | Recorder 30 days, alarms and event log |
| Qualification | pre-qualified WHO PQS |
CECryopreservation · CryoLine line −150 °C / LN₂
Complete cryopreservation solution from −150 °C (mechanical) to −196 °C (liquid nitrogen vapor phase) for biobanks, stem cells, gametes and genetic material. Low rate of static evaporation and intelligent monitoring of level and temperature.
| Temperature | −150 °C (mechanical) · up to −196 °C (LN₂) |
|---|---|
| Capacity | 2 L to 1,340 L / Thousands of vanes and vials |
| Static evaporation | 0.07 to 5.5 L/day according to the model |
| Mouth / Neck | 30 mm to 1,000 mm inner diameter |
| Series | CryoBio, Biobank, Smart Monitored, Transport Dryshipper |
| Security | self-pressurized, level sensors and O₂ alarm |
CECell Culture · CellCulture CO₂ Line
CO₂ incubators with precise temperature, CO₂ and moisture control for cell and tissue culture. Thermal or infrared conductivity sensors, high temperature sterilization cycle and electropolished stainless steel chamber prevent contamination.
| Temperature | Environment +3 °C to 55 °C, uniformity ±0.1 °C |
|---|---|
| CO₂ | 0–20%, CT or IR sensor |
| Capacity | 50 L a 240 L |
| Convection | Natural or forced air |
| Decontamination | Cycle at 180 °C / UV optional |
| Chamber | 304 stainless steel electropolished, removable shelves |
CE · TÜV SÜD · NSF 49 · EN 12469Biosafety · BioGuard Class II Line
Class II Biological Safety Cabins for the protection of the operator, product and environment in the handling of biological hazard agents. HEPA/ULPA filters, controlled descending air flow and speed alarm system ensure containment according to international standards.
| Class | Class II (A2 and related configurations) |
|---|---|
| Percolation | HEPA H14 99.995 %@0.3 µM or ULPA U15 99.9995 %@0.12 µM |
| Downflow | 0,28 a 0,35 m/s |
| Configuration | Single or double HEPA; widths from 0.7 to 1.8 m |
| Structure | Stainless steel work surface, motorized front glass |
| Ventilation | Low consumption EC motor with automatic compensation |
CE · TÜV SÜDClean environment · CleanFlow line
Horizontal and vertical laminar flow benches that create class 5 ISO work area, protecting samples and processes against particles. Ideal for preparing media, assembling sensitive electronics and non-hazardous sterile manipulation.
| Air class | ISO Class 5 in the work zone |
|---|---|
| Flow | horizontal or vertical, HEPA H14 filter |
| Lighting | ≥300 lux (default) to ≥1000 lux |
| Structure | stainless steel, digital control panel |
| Feeding | 115 V/60 Hz, 220 V/50–60 Hz |
| Options | ductless exhaust chapel for vapors |
CESeparation · SpinPro Line
Low, high speed and high capacity centrifuges, with and without refrigeration, for separation of blood, cells, proteins and clinical samples. Fixed rotors and interchangeable tilts serve from PCR microtubes to 500 ml bottles.
| Max speed. | 5,000 to 16,500 rpm |
|---|---|
| RCF | up to tens of thousands of ×g according to rotor |
| Samples | 4×8×0.2 mL (PCR) up to 4×500 mL |
| Refrigeration | Control from −20 °C to +40 °C in refrigerated versions |
| Rotors | Fixed angle, tilting and sealed (biosafe) |
| Format | Bench, compact hydrocarbon and floor |
CESample Preparation · FlexiFreeze Line
Freeze drying freeze drying of organic, pharmaceutical and food products, preserving structure and activity. Low temperature condensers and stable vacuum chambers for bench, laboratory and pilot scales.
| Condenser | Low temperatures for efficient ice capture |
|---|---|
| Formats | Bench, lab and pilot |
| Chamber | Heated shelves, vacuum control |
| Control | programmable cycle revenue, process record |
| Applications | biopharmaceuticals, microbiology, food, materials |
| Hygiene | Stainless steel surfaces, drainage and easy cleaning |
CEAnalytical Instrumentation · OptaSpec UV-Vis line
UV-visible spectrophotometers for quantification of nucleic acids, proteins and colorimetric assays, including micro-volume (nano) and single/double beam models. Stable optics and intuitive software for analytical routine and quality control.
| Spectral range | Ultraviolet and visible (UV-Vis) |
|---|---|
| Models | microvolume (nano) and cuvette |
| Series | Basic V, Advanced X and above Q |
| Applications | DNA/RNA, proteins, enzymatic kinetics, colorimetry |
| Source | Long life lamps, self-calibration |
| Data | Export and compliance with good practices |
In addition to the main lines, we offer support equipment to complete your laboratory and health infrastructure.
Autoclaves and decontamination systems for instruments and waste.
Smart coolers with RFID and automated pharmacy solutions.
Equipment for treatment and safe disposal of medical waste.
Total Organic Carbon Analyzer (TOC) and microwave digestion.
Greenhouses and cabinets for heating fluids and solutions.
Cold rooms and custom modular freezing rooms.
Cold chain engineering, regulatory compliance and specialized technical support.
Microprocessed control and air circulation that keep the temperature stable throughout the chamber, point by point.
Inverter compressors, vacuum insulation and low-energy versions reduce consumption and operating costs.
Continuous registration, multilevel alarms and connectivity for traceability and real-time auditing.
CE, UL, ENERGY STAR certifications, ATEX, WHO PQS, NSF 49 and EN 12469 according to the application.
Ultrafreezer operates at ultra-low temperature (−40 to −86 °C) for long-term preservation of biological material such as cells, DNA/RNA and vaccines. Biomedical freezers work between −10 and −60 °C, suitable for plasma, reagents and diagnostic kits.
Yes. The lines have international certifications such As CE, UL, ENERGY STAR, ATEX, WHO PQS, NSF 49 and EN 12469, depending on the category, in addition to monitoring and alarm systems for traceability.
Yes. The equipment supports integrated registers and IoT connectivity for continuous temperature monitoring, real-time alerts and auditable event history.
Yes. The portfolio covers from cryogenics with liquid nitrogen (−196 °C) and Ultrafreezers (−86 °C) to 2–8 °C coolers, including solutions for vaccines, blood and cell culture.
Talk to our experts to receive technical recommendations, specifications sheet and personalized quote for your application.
