From primary field sensorization to advanced electrical quality diagnostic (QEE): Labsolutions integrates Swiss and German precision instrumentation, world-leading QEE analysis and high-performance control and telemetry platforms — a solution one-stop shop For the entire lifecycle of clean energy generation, transmission and distribution assets.
Each layer of architecture is covered by a leading global brand — and everything is delivered, integrated and supported by a single engineering partner in Brazil.
Transducers SINEAX with very high level galvanic insulation, immune to electromagnetic interference; Absolute encoders and inclinometers KINAX for severe vibration, dust and extreme temperatures. Conversion of mechanical and electrical quantities to 4–20 mA, HART and industrial networks.
Camille BauerENERGYMID meter calibrated and certified (MID approval) for billing and apportionment; Suitcases PROFITEST for commissioning (grounding, insulation, functional tests); Continuous monitoring of insulation resistance in IT/DC networks.
Gossen MetrawattPortable and fixed HDPQ analyzers with high-speed sampling: capture of sags, swells, transients, flicker and harmonic content up to 63rd order, with automatic issuance of IEC 61000‑4‑30 reports Class A, IEEE 519 and PRODIST Module 8.
DranetzHigh-speed programmable control platform with redundant CPUs for critical applications of substations and power plants, full support for electricity sector protocols (IEC 60870‑5‑104, IEC 61850, DNP3 with authentication secure) and MQTT/OPC UA native connectivity to cloud.
LabSolutions IntegrationThe harmonious integration of the layers makes it possible to build a single stream of operational and diagnostic data — without "automation islands" and without engineering rework.
Rotation angle, tilt, level, analog signals with galvanic insulation
Voltage, current, class energy, continuous AC/DC insulation
Execution of the power plant logic, mesh of trackers, sending to ONS/SCADA
Energy quality certification, disturbance analysis, normative reports
| Layer | Level in architecture | Input / Sensorization | Output / Communication | Role in LabSolutions Solution |
|---|---|---|---|---|
| CAMILLE BAUER Sensors & Transducers |
Field / Primary Instrumentation | Rotation angle, tilt, level, electric analog signals | 4–20 mA Modbus Profinet SSI |
Reliable sensorization of solar trackers (trackers), gates and electrical signal conditioning with galvanic insulation. |
| GOSSEN METRAWATT Measurement & Safety |
Class measurement & electrical safety | Voltage, current, energy, insulation resistance DC/AC | Modbus TCP M-Bus Dry contact |
Operational safety guarantee, grounding/isolation tests and measurement of class precision for invoicing and apportionment. |
| CONTROL PLATFORM PLC & Telemetry |
Control, logic and communication | Digital/analog inputs, industrial field networks | IEC 60870-5-104 IEC 61850 DNP3 MQTT OC UA |
System brain: execution of control logic, management of the trackers/usina mesh and sending telemetry to the ONS/SCADA with CPU redundancy. |
| DRANETZ QEE analyzers |
Diagnosis and Audit | High sampling waveforms (V and I) | Ethernet USB Modbus TCP PDF reports |
Power quality certification for ONS, disturbance auditing and commissioning of inverters and BESS systems. |
Approved and recognized worldwide instruments, supplied, integrated and supported by Labsolutions in Brazil.
Eight reference architectures, with the complete technical thread — from the sensor in the field to the report delivered to the regulator. Each project is adapted to the reality of the asset and the client.
Scenario: Solar park with single-shaft trackers where positioning failures reduce yield and strong winds threaten the mechanical integrity of the tables.
RS‑485 or analog inputsScenario: Network connected to the network needs to meet the requirements of the active/reactive power control ONS, power factor and voltage in the PAC — with continuous evidence of power quality.
Modbus TCP in quick cyclesIEC 60870‑5‑104 / DNP3 with secure authentication up to the COS/agentScenario: Silent losses from degraded strings, burned fuses and high-resistance connections only appear on the monthly generation closure—too late.
RS‑485/Modbus RTU by skidMQTT/OPC UA: Strings ranking, heatmap by skid and automatic work orders for the O&M teamScenario: PCH in operation for decades with hydraulic controls and obsolete relays, without spare parts, without supervisory and with manual registration of levels and openings.
IEC 60870‑5‑104 for unassisted plant operationScenario: Container storage system where a current leak in the DC bus or repeated switching transients can lead to thermal failure and cell life loss.
Modbus TCPScenario: Industry in the free market needs to accurately apportion the cost of energy between production lines, identify inefficient cost centers and support contract renegotiation.
RS‑485/Modbus Concentrates all meters on an acquisition controller, which totals consumption, demand and power factor per cost center at 15-minute integration intervalsScenario: ACCESSOR needs to prove voltage compliance in steady state, imbalance, flicker and harmonic distortion at the point of connection — or investigate quality complaints with the distributor.
Scenario: Recurring fines for reactive surplus, heating of transformers and improper performance of protections — typical symptoms of high harmonic distortion by inverters and rectifiers.
From the field bus to the ONS operation center, each interface is specified, mapped and documented by LabSolutions engineering.
Substation communication: IED modeling, MMS reports and GOOSE messages for quick interlocks between spans.
Remote TCP/IP for supervision and command with COS of agents, distributors and ONS.
Telemetry with Secure authentication For remote links that require encryption and command integrity.
Universal integration with inverters, meters, BMS, protection relays and QEE monitors — documented register maps.
Native connectivity with cloud platforms and historians: telemetry by exception, standardized data models and TLS.
Instrumentation layer: isolated analog signals, sensor networks and large-scale energy meters reading.
Reports and analyzes issued automatically by the instruments, revised and signed by Engenharia Labsolutions.
QEE measurement methodology with accuracy and temporal aggregation defined by norm — comparable and legally defensible results between instruments.
Steady Stress (DRP/DRC), imbalance, flicker, harmonics and short-term events — complete campaigns of 1,008 valid intervals.
Harmonic distortion limits of voltage and current (THD/TDD) at the common coupling point, with analysis in harmonic order up to 63rd.
Supervision and control in the standard of network procedures: remote control, active/reactive power control and Evidence of QEE at the point of connection.
Certified meters for commercial transactions and auditable apportionment — factory metrological traceability.
Grounding, insulation, DR and continuity tests in accordance with low and medium voltage electrical installation standards.
Assembly and supply of complete, pre-configured and factory-tested control panels (documented FAT).
Specialized field services with certified instruments and own engineering.
Recurring packages of predictive and corrective maintenance for solar parks and industries.
EPCist integrators, SHP operators and asset managers in the free energy market: get to know the LabSolutions integrated demo kit and see the solution working from end to end.
Schedule technical demonstration