Nitrogen gas (N₂) is used in laboratories and in industry as carrier gas, purge gas, inert atmosphere and protective gas. Instead of relying on cylinders, many users started to produce their own nitrogen with a nitrogen generator, which separates the N₂ from the compressed air at the place of use. This guide explains the technologies, applications and criteria for choosing the right equipment.
As the generator separates nitrogen from the air
The air contains about 78% nitrogen and 21% oxygen. The generator receives clean and dry compressed air and removes oxygen, moisture and CO₂ by one of two technologies:
- PSA (adsorption with pressure variation): two columns with a carbon molecular sieve alternate; Oxygen is retained and nitrogen passes. It reaches purities from 99% to 99.999%.
- Membrane: bundles of hollow fibers let oxygen and moisture permeate faster than nitrogen. It is simple and silent, with typical purities of 95% to 99.5%.
Main applications
- Chromatography and LC-MS: nebulization and curtain gas on mass spectrometers, and GC carrier gas.
- Sample preparation: evaporators and nitrogen blow concentrators.
- Inert atmosphere: feeding gloveboxes, ovens, ovens and reactors.
- Industry: modified atmosphere packaging, tank inertization, laser cutting and electronics.
How to choose
- Purity: define the purity required by the application. LC-MS usually works with 95% to 99%; GC, sensitive and electronic inert atmospheres require 99.99% or more.
- Flow: add up the consumption of all equipment connected to the generator, in L/min, and add a margin for spikes and expansion.
- Output pressure: check the input pressure required by each equipment.
- Air Source: the generator can have an integrated compressor or use the compressed air of the installation; In this case, the air needs to be oil-free, filtered and dried.
- Installation environment: consider noise, heat dissipation and countertop or floor space.
Generator or cylinder?
The cylinder makes sense for low and sporadic consumption. For continuous use, the generator eliminates cylinder replacement, high pressure handling and the risk of interrupting an analysis due to a lack of gas, in addition to offering constant supply and stable purity.
Nitrogen gas and liquid nitrogen
If the application requires cryogenic temperatures, such as cryopreservation or detector cooling, the path is liquid nitrogen. See the liquid Nitrogen Guide.
Meet the models in gaseous Nitrogen Generators and the complete line of gas Generators (hydrogen, zero air and purge gas).
FAQ
What nitrogen purity do I need for LC-MS?
Most mass spectrometers work with nitrogen between 95% and 99% for nebulization and curtain gas. See your equipment manufacturer specification.
Can I use the compressed air in the building?
Yes, as long as the air is free from oil, filtered and dried, with sufficient pressure and flow. Otherwise, prefer a generator with an integrated compressor.
Can a generator power various equipment?
It can, as long as the total flow and pressure are within the generator capacity.