Ideal for advanced search applications requiring high current capacity while maintaining analytical accuracy and flexibility.

Potentiostat/galvanostat of single channel with FRA
Current range: ±10 a max.
Voltage Scan Range: ±10 V
EIS frequency range: 10 µHz - 2 MHz
Compatible with Windows, macOS and Ubuntu through the Squidstat and API (Application Programming Interface).
Integrated memory (16 GB) automatically backs up all channel data for future recovery.
Multiple units can work simultaneously with other Squidstat models.
Made in the USA





Galvanostatic electrochemical impedance spectroscopy (GIs)
Electrochemical impedance spectroscopy Potentiostatic (PEIS)
Mott-Schottky (single frequency and multifrequency)
Battery Capacity
Load/Disload (C constant / V constant)
Load/discharge (Constant Resistance / Power Constant)
Chronoampperometry
Chronopotentiometry
Constant power
Constant resistance
Cyclic voltmetry (CV)
Differential pulse voltammetry (DPV)
Intermittent galvanostatic titration technique (GITT)
Intermittent potentiostatic titration technique (PITT)
Linear scan aperometry
Voltammetry Linear Scan (LSV)
Normal Pulse Voltammetry
Open Circuit Potential Monitoring
Rotary Ring Disk Electrode (RRDE)
Square Wave Voltammetry
Ladder Voltammetry
Direct Current Experiments
AC Experiments
DC Parameters
Working Electrode (V)
Working Electrode (MV)
DC Work Electrode (V)
DC Working Electrode (MV)
Counterelectrode (V)
Counterelectrode (MV)
Current (A)
Current (MA)
DC current (A)
DC current (MA)
Working electrode vs. NHE (V)
Current Density (A/M2)
Current Density (A/cm²)
Power (W)
Accumulated Load (MAH)
Accumulated Load (C)
Capacity (Mah)
Energy (WH)
Load status (%)
Discharge depth (%)
dQ/dV (mAh/V)
1 / √(Time) (1/√S)
Resistance (OHM)
Number of cycles
Parameters CA
Frequency (Hz)
Phase (Grades)
|Z| (ohms)
Z' (ohms)
-z'' (ohms)
Z'' (ohms)
Amplitude (A)
Amplitude (V)
Amplitude (MV)
Duration of each Frequency (s)
Number of Cycles
THD (%)
Serial ((1/C2)(1/µF2))
Serial ((1/C)(1/µF))
Parallel ((1/C2)(1/µF2))
Parallel ((1/C)(1/µF))
Additional Parameters
Temperature (Grauses, °C)
PC Date/Time Stamp
Time UTC (S)

|
Potentiostatic Input/Output
|
Values
|
|---|---|
|
Compliance Voltage
|
±10 V
|
|
Voltage Scan Range
|
±10 V
|
|
Number of Voltage Ranges
|
4 Ranges, [±10 V, ±5 V, ±1 V, ±0.5V]
|
|
Applied Voltage Accuracy
|
0.1% of the reference value, 1 mV min
|
|
Applied Voltage Resolution
|
0.003% (30.52 ppm) of the range, 15 μV min
|
|
Measured voltage accuracy
|
0.1% of the measured value, 1 mV min
|
|
Voltage resolution measured
|
0.003% (30.52 ppm) of the range, 15 μV min
|
|
Time resolution
|
10 ns
|
|
IR compensation limits
|
1 V
|
|
Galvanostatic input/output
|
Values
|
|---|---|
|
Current range
|
±10 A
|
|
Number of current intervals
|
9 ranges, [1 μA to 10 A]
|
|
Precision of the applied current
|
0.1% of the range, 1 in the min
|
|
Applied current resolution
|
0.003% (30.52 ppm) of the range, 30 Pa min
|
|
Current accuracy measured
|
0.1% of the range, 1 in the min
|
|
Current resolution measured
|
0.003% (30.52 ppm) of the range, 30 Pa min
|
|
General Specifications
|
Values
|
|---|---|
|
Channels per unit
|
1
|
|
Operating modes
|
Pot / Gal / ZRA /FRA
|
|
Cellular Connections
|
5 Electrodes
|
|
ADC/DAC resolution
|
16-bit resolution
|
|
Rate of change (charge of 1 kΩ)
|
1 MV/s (-1 V a +1 V)
|
|
Minimum DC data recording interval
|
200 µs
|
|
Hardware sampling interval Shortest DC Data
|
7,5 µs
|
|
Floating/Terrestrial Mode
|
Both (changeable)
|
|
Input Impedance
|
10 tera-ω (Typical)
|
|
Input Polarization Current
|
10 Pa (Typical)
|
|
Data backup memory
|
16GB integrated
|
|
Dimensions and weight
|
24 cm long x 17 cm wide x 13 cm high, 3.5 kg
|
|
Channel cable length
|
1 m
|
|
Computer interface
|
1 USB per unit
|
|
Operating temperature range
|
0 a 40 ℃
|
|
Minimal/maximum scan rate
|
15 µV/s Minimum, 25V/s maximum with sampling of 10 mV
|
|
Lower pulse width
|
375 µs
|
|
Lower potential step for scanning voltammetry
|
0.003% (30.52 ppm) of the range, 15 μV min
|
|
Square wave voltammetry Maximum frequency
|
2 kHz (-1 V to +1 V)
|
|
Power supply requirements
|
100 – 240 VAC, 50 – 60 Hz
|
|
Impedance Analyzer
|
Values
|
|---|---|
|
EIS Frequency Range
|
10 μHz to 2 MHz
|
|
Accuracy of the frequency AC
|
0.005% (50 ppm) or better
|
|
AC frequency resolution
|
18 bits, 0.0004% (3.81 ppm), 3 µHz minimum
|
|
EIS amplitude resolution
|
24-bit resolution
|
|
EIS Potentiostatic Range
|
≤ 100% of the range, 10 V max.
|
|
EIS Potentiostatic EIS amplitude resolution
|
0.000012% (0.12 ppm) of the setpoint/measured
|
|
Galvanostatic Amplitude
|
≤ ≤ 100% of the range, 10 to max.
|
|
EIS galvanostatic EIS amplitude resolution
|
0.000012% (0.12 ppm) of the range
|
±10 A potentiostat with EIS up to 1 MHz
Highlights Blanket Squidstat:
Each Squidstat Decka includes a 100 cm working electrode cable, a 100 cm counter electrode cable, a 100 cm detection cable with reference connections, work detection and counter detection, a USB cable and a cable power supply to connect to an electrical outlet. The Squidstat software User interface and unlimited remote technical support are included in the purchase.
|
Price per unit ($USD) |
$13,900 |
|
Channels per unit |
1 |
|
Operating modes |
Pot / Gal / ZRA / FRA |
|
Cellular connections |
2, 3, 4 or 5 electrodes |
|
ADC/DAC resolution |
16-bit resolution |
|
Swing rate (without load) |
5MV/s |
|
Maximum sampling speed |
100,000 samples/s |
|
Floating and/or grounding |
Both (Change) |
|
Input Impedance |
> 10 Tera-ohm |
|
Input Polarization Current |
< 1 pA |
|
Data Backup Memory |
16 GB |
|
Physical Dimensions |
23 cm x 17 cm x 13 cm |
|
Channel Cable Length |
100 cm |
|
Computer Interface |
1 USB per Unit |
|
Power Supply Requirements |
100 – 240 VAC 50 – 60 Hz |
|
Compliance Voltage |
±10 V |
|
Voltage Scan Range |
±10 V |
|
Number of Voltage Ranges |
4 Ranges, (0,5V, 1V, 5V, 10V) |
|
Potential Applied Precision |
0.1% of the Setpoint, 1 mV min |
|
Applied Potential Resolution |
0.003% range, 15 μV min |
|
Measured Potential Accuracy |
0.1% Reading, 1 mV min |
|
Measured Potential Resolution |
0.003% of range, 15 μV min
|
|
Maximum current |
±10 A |
|
Current intervals |
9 ranges, (1 μA a 10 A) |
|
Current accuracy applied |
0.1% of the range, 1 nA min |
|
Current resolution applied |
0.003% range, 30 pA min |
|
Current accuracy Measure |
0.1% of range, 1 nA min |
|
Current resolution Measure |
0.003% range, 30 pA min |
|
EIS Frequency Range |
10 μHz to 1 MHz |
|
AC frequency accuracy |
0.005% or better |
|
AC frequency resolution |
0.0004%, 3 µHz min |
|
Potentiostatic amplitude |
≤ 100% of the range, 10 V máx. |
|
potentiostatic Amplitude Resolution |
25 µV @ 1mV 250 µV @ 100mV 2,5 mV @ 10 V |
|
Galvanostatic Amplitude |
≤ 100% of the range, 10 A máx. |
|
galvanostatic Amplitude Resolution |
0.025% of applied to 100% of the range |
LabSolutions is the exclusive representative of Admiral Instruments in Brazil.