The ISX-3mini brings the ISX impedance analysis platform to a compact, lightweight 12 VDC format, ideal for laboratories and technical installations where space, location or system integration are important.

BROADBAND BEHOLDDetailed impedance spectroscopy, from slow processes to the MHz range.
WIDE MEASURING RANGESpecified magnitude accuracy of 0.1% and phase precision of 0.1°.
COMPACT FORMATA professional impedance analyzer that takes up little space in the installation.
CC powerDirect integration into compact experimental and automated systems.
The compact format provides greater freedom in relation to the location of the analyzer and the way it integrates the experiment.
Place it next to the device under test, snap it into tight settings, integrate it into a 12V system or move it easily between measurement locations.
Position the analyzer next to prototypes, fixing devices, microscopes, fluid systems, environmental equipment, robotics or other instruments, without having to reorganize the entire bench around a single compartment.
The box's reduced size, DC power and standard control interfaces make the ISX-3mini easier to include in experimental and automated systems.
Position the analyzer next to the sensor, device or accessory when local placement makes the overall configuration simpler and more straightforward.
Relocate the analyzer between laboratory stations, demonstrators and compact technical configurations without the need to dedicate a complete tabletop instrument at each location.
The ISX-3mini uses the ISX impedance analysis platform on a substantially smaller 12 VDC instrument. The exact configuration must be selected based on the physical configuration, the measurement range and the required interfaces.
The useful performance of an impedance analyzer is determined by the combination of the frequency and impedance of the device under test (DUT), and not by a single optimal precision value.
The ISX-3mini specifies a magnitude magnitude of 0.1% and 0.1° phase. The reference precision contour shows where the most robust measurement region is located in the wide impedance/frequency space, reaching a magnitude accuracy of 0.01% in a wide central region under documented conditions.
Visual: Outline Z/F released. Caption: Find the expected accuracy region at the impedance and frequency relevant to the application.
Adjust the precision setting according to the importance you give to the acquisition time or the least dispersion of the measurement.