The ISX-3 EIT starts with all the measurement features of the ISX-3 impedance analyzer from Sciospec and adds a 32 or 64-port multiplexer (any-for-any) and a measurement mode EIT Dedicated.

COMPLETE IMPEDANCE SPECTROSCOPY
FREQUENCY POINTS
FLEXIBLE ELECTRODE PORTS
IMPEDANCE ACCURACY
SAME ARRANGEMENT OF 32/64 ELECTRODES → EIS MODE: SELECT 2/3/4 ELECTRODES → DETAILED SPECTRUM | EIT MODE: SELECT INJECTION PAIR → SEQUENTIAL SCAN OF ARRANGEMENT VOLTAGES → NEXT PAIR → FRAME EIT → RECONSTRUCTION
Use measurements with 2, 3 or 4 electrodes, wide scans, automatic track adjustment, precision settings, and standard analysis ISX-3 across the flexible multiplexer.
Define current injection pairs and frequency blocks. For each injection state, the ISX-3 EIT sequentially measures the voltages of the selected array and stores the result as a EIT frame for image generation or custom analysis.
ISX-3 uses a single high-performance analyzer and multiplex through the detector set. This preserves analyzer-level spectroscopy, but does not offer simultaneous voltage sampling or high frame rates of the dedicated EIT systems.
Use the same instrument when the project switches between EIS detailed location, multiplexed measurements with multiple electrodes, and tomographic reconstruction, rather than keeping sets of separate measurements.
Main specifications for the first technical qualification. The ISX-3 EIT combines the ISX-3 analyzer specifications already disclosed with the MUX32/MUX64 and the EIT option documented in the current ISX-3 manual.
ISX-3 EIT with 32/64 port matrix — Show the analyzer and multiplexer physically connected to a ghost, sensor or electrode structure so that the product is immediately understood as something more than a standard ISX-3.
EIS Spectrum Detailed — Use a real Bode or Nyquist view from the ISX-3 software. This is the functionality that dedicated EIT products do not try to replace.
EIT Injection Pattern and Pattern — Display the frequency blocks and configurable injection pattern of EIT workflow instead of a generic software screenshot.
Use dense frequency scans and configurable injection patterns when the contrast is dispersive and a single-frequency EIT image does not capture all behavior.
Investigating spatial differences in conductive, dielectric or interfacial behavior, where the sample slowly changes enough to allow for sequential acquisition and detailed spectroscopy, is valuable.
Switch between detailed spectra of 2, 3 or 4 electrodes and spatial measurements EIT, while the sensor geometry, interfaces and analysis are still under development.
Use EIS and EIT open workflows when the project is developing new spatial impedance methods, rather than simply using a fixed imaging protocol.
Use the disclosed accuracy contour and a representative impedance spectrum of the ISX-3 manual to show the usable frequency range-impedance range and how the measurement performance changes toward its limits.
The existing EIDORS application note demonstrates the data path Sciospec EIT for external processing and reconstruction - useful when the default image workflow is not the end of the analysis.
Use the conventional ISX-3 electrochemical impedance spectroscopy with 2, 3 or 4 software configurable electrodes when it is necessary to separate the cables, contacts or interfaces from the sample response electrodes.
Adjust the ISX-3 precision setting when a difficult impedance measurement benefits from greater measurement stability rather than the shorter acquisition time.
Use open circuit compensation, short circuit and load to compensate for the parasitic capacitances of the configuration. ISX-3 also provides DC polarization of +/-1 V on the main measurement port when the experiment requires it.
The extension port supports application-specific user interfaces and digital I/O when the default connection is not enough. Refer to the exact interface and the measurement path with Sciospec.
Choose the frequency range, the number of EIT-MUX channels, the front panel connectors and the Phantom/Device accessories that match your EIT or EIS multiplexed workflow.
10 MHz
40 MHz
32 channels
64 channels
Medical power supply
Insulation class II, in accordance with the EN60601-1 standard.
Io door
Additional connector with digital I/O, serial interfaces and NTC temperature sensors for connecting external devices, intelligent sensors, etc.
Iso holder
Medical grade isolated additional connector with digital I/O, serial interfaces and NTC temperature sensors for connecting external devices, intelligent sensors, etc.
Medical grade envelope modification
Synchronization port
Ultra-fast hardware synchronization through an incoming and outgoing synchronization port (for example, through a low-level isolated interface or an optional isolated synchronization module), connector type: SMA
Battery
Integrated battery for measurements of up to 3 hours.
WI-FI
BNC
SMA
MCX
Banana connector
DSUB
Others/Customised
Please specify.
Ghost Tank EIT Standard
Ghost Tank EIT Custom (specify, please)
AC coupling Interface for the first 4-point channel
Y2 capacitors in accordance with IEC 60384-14:2013 with high levels of insulation. With the internal circuit operating in the SELV domain, they serve MOPP ratings of 2.
Compensation Kit
6 high-precision wired resistors (1 Ohm, 10 Ohm, 100 Ohm, 1 kOhm, 10 kOhm and 100 kOhm) for connection to different devices, such as 10 MHz component test devices or 30 MHz or Kelvin cables; Includes case for safe storage.
Dielectric test device
To measure sheets and thin films with a thickness of up to 10 mm.
Liquid test device
To measure liquids and solutions
10MHz component test device
To facilitate the connection of wired components; measurements up to 10 MHz; Short circuit board included.
30 MHz component test device
To facilitate the connection of wired components; measurements up to 30 MHz; Short circuit board included.
SMD test device
For connection of SMD components; Types of SMD encapsulation from 0201 to 2920.
BNC - BNC 1 m
BNC cables with 1 m Kelvin clip
BNC - 4 mm, 1 m banana plug
BNC - MCX 0.8m
1 m MUX cable set
RG178; MDR - Banana Plug (+ Alligator Claws)
Base unit
ISX-3 EIT
Channel
—
Channel count EIT-MUX
—
Additional functionality
—
Front panel connectors
—
Accessories
—
Cable Sets
—
Our application engineers will analyze your configuration.
Talk to an ExpertConfigure measurements with 2, 3 or 4 electrodes, frequency scans, excitation, accuracy and compensation; Inspect spectra in the ISX-3 standard workflow.
Create frequency blocks EIT, set the amplitude and accuracy of the current, and use predefined or user-defined injection pairs around the 32/64-port array.
Analyze the complete EIT frames, the voltage spectra, the voltage differences and the U-shaped graphs to understand the contour measurements behind the image.
Use the built-in time/frequency difference image workflow for standard adjacent circular configurations, or export raw data EIT to MATLAB/EIDORS and custom reconstruction.
Dedicated systems acquire all voltage channels synchronously for each injection state and are the ideal solution for dynamic images and high temporal performance. Choose the ISX-3 EIT when the sample is slow enough for sequential scanning and the spectrum is more important.
If you only need detailed impedance spectra on one or a few conventional measurement connections, the standard ISX-3 is simpler. Add EIT when the project actually requires a spatial measurement with 32/64 electrodes or a workflow EIT.
A separate analyzer and multiplexer can be perfectly suited for slow automated measurements. The ISX-3 EIT becomes attractive when you want an integrated control workflow, port routing and EIT, rather than building the spatial acquisition around separate instruments.
The custom hardware offers complete freedom. The ISX-3 EIT is more robust when scientific work involves impedance, materials, sensors or reconstruction and you want an integrated professional analyzer.
Many projects maintain the ISX-3 EIT standard. Others eventually require the adaptation of the measurement to a special set of electrodes, the integration into a larger experimental system or the incorporation into dedicated hardware. These are distinct extension paths – not a mandatory sequence.
Sciospec can support the part that actually becomes limiting: the physical interface, the application-specific frontend, the software/system integration, or a separately designed OEM implementation.
Custom cables, printed circuit boards adapters or brackets can convert a non-standard set or sensor to the connection scheme ISX-3 EIT.
If the sensor requires additional analog or digital functionality, Sciospec can evaluate a dedicated interface around the ISX-3 extension port.
Use the Sciospec COM interface, synchronization and I/O options to integrate measurements into automated experiments, test systems or machines.
For recurring products or instruments, Sciospec can define the scope of dedicated electronics, switching, firmware, mechanics and production support around the validated measurement.
Choose 32 or 64 ports EIT/MUX, the ISX-3 parser configuration, interfaces, accessories and quantity.
Send the electrode map, the expected impedance, the frequency range, the number of spectral points, the injection sequence and the acceptable full scan time. we will analyze if the ISX-3 EIT is the most appropriate option.
If the real need is dynamic image, synchronized voltage acquisition or high frame rate, compare EIT16 and EIT32/64/128+.
