The REFF reference junctions are manufactured from an electrochemically conductive polymeric matrix and loaded with salt. When installed on an electrode, there is no porous junction that allows liquids to contact between the process fluids and the internal reference semi-cell (permanently sealed) of Ag/AgCl. Reff provides a stable MV output for measurement and ensures that process fluids do not poison or exhaust the electrode or electrolyte from the reference cell.
Reff continues to function even when completely coated, As long As the coating remains moist and conductive. Even when a severe sensor coating inevitably decreases the electrode response, the pH measurement remains accurate. Proven applications range from clean and cold water from rivers to crude oil, sewage sludge and aggressive chemical flows – all of them are solved with a reference interface Reff.
The Reff Electrode is the reliable sensor that the market has been waiting for – virtually maintenance-free, with exceptionally long life and superb stability.

The pH REFF reference electrodes are constructed with an advanced polymeric material that provides an electrochemical connection with the reference electrode within the probe, without any direct contact with the process fluid. This eliminates the measurement stability problems and shorter life of the probe observed in traditional probes. The method of construction of the Refex sensors uses a large section of the electrode body to provide the reference connection, drastically reducing the measurement error introduced by the probe's outer coating material. The pH and ORP Refex sensors are reliable, accurate, stable and offer exceptionally long service life (even in severe petrochemical applications, probes are expected to last 5 times longer than conventional models), providing real savings in maintenance costs. and dramatically increasing the quality of the process.
Probes with non-porous REFEX™ references have these very real advantages:
The main pH measurement problems, such as drift, slow response and measurement error, are often associated with the porous reference junction or the conducting salt bridge of the conventional electrodes. Because it is porous, the reference junction is very sensitive to fouling, poisoning, temperature/pressure variations and electrolyte diffusion/dilution within the reference semicell, and all these factors can have a significant impact on measurement performance. The short shelf life of conventional electrodes in aggressive applications is common and, in addition to the cost of replacing electrodes, many hours of work are spent on maintenance activities. The cost of using conventional electrodes, even the so-called "long service life" and "for robust applications" models, is high and represents a great opportunity to reduce costs.
The REFEX electrodes still use an Ag/AgCl element in a 3 mol/L KCl electrolyte (as well as conventional technology probes, therefore, work with many standard pH transmitters), but additionally use a patented conductive polymeric material such as barrier between the process and the reference electrode. Unlike conventional electrodes that use open channels, diaphragms or other means to connect the reference electrode to the process, this solid barrier is not porous, so that the problems caused by incrustation, poisoning, temperature/pressure changes and diffusion/dilution of the electrolyte are essentially mitigated.
In simple terms, the REFF reference electrodes represent an improvement over conventional designs, eliminating the need for a porous liquid junction in a pH (or ORP) measurement circuit.
The non-porous nature of Reff:
For example, raw water (from reservoirs, lakes and rivers) can be extremely cold, with low ionic strength and traces of magnesium and iron. Conventional pH sensors with porous reference junctions can quickly contaminate due to the presence of these trace metals, requiring frequent cleaning and recalibration. Due to the difference in the concentration of salt between the reference electrolyte (typically KCl 3 mol/L) and the water to be measured, diffusion occurs through the porous junction, depleting the electrolyte of the reference cell. This causes a diffusion potential error, which is significant when you need to maintain an accurate pH value. When conventional electrodes with porous junctions are installed in applications with low ionic force water, they often show instability in the form of continuous drift.
The opposite occurs when working with process solutions with high ionic force. In this case, the diffusion occurs in the opposite direction, with a consequent change in the properties of the electrolyte.
Because it is non-porous, REFEX eliminates the measurement error caused by the diffusion potential. There is no loss or dilution of the electrolyte during the use of the electrode, which provides an extremely stable reference output (drive < 1 mV/month). The entry of toxic substances is eliminated, considerably prolonging the useful life of the electrode.


Electrode incrustation is one of the main problems that require frequent maintenance and recalibration. The problem with conventional electrodes lies in the porous liquid junction of the reference electrode. This porous junction, whether ceramic, Teflon, paper, wood or other materials, can, over time, become obstructed by the process fluid, increasing impedance and affecting performance. This obstruction can become so severe that the electrode stops responding completely. Limestone, manganese, precipitation between hydrogen sulfides and AgCl, and accumulation of proteins/fats in sewage and industrial effluents are examples of materials that can affect the performance of the electrode in this way. obstruction by fine particles – pigments and dyes, etc. – It is particularly harmful and has proven to significantly shorten the life of conventional electrodes significantly.
The reference electrodes are low impedance sensors (typically 10 kΩ), while the pH glass element is a high impedance sensor (typically 100 MΩ). Coatings and deposits on sensors can increase impedance by 1 MΩ; This does not represent a major problem for the pH glass electrode – the impedance changes to 10¹ MΩ (increase of 1%) – however, the same effect on the reference side (through the porous junction) changes the impedance of 10 kΩ to 10¹⁰ KΩ – A change of several orders of magnitude, and that is exactly where the problem lies. A solution to this problem has been the use of a fluid junction electrode, where the liquid electrolyte is pressurized to create a positive flow of KCl through the junction and keep it free of contaminants. Although this helps, it requires a lot of maintenance and consumables, in addition to also allowing the poisoning of the reference element with consequent precipitation inside the sensor's body. The pressurization and flow of the electrolyte seal the destination of the electrodes, blocking the junction from the inside!
Reff is much more resistant to fouling and waste accumulation. Because it is non-porous, there is nothing that can obstruct the flow, and as long as any coating on the electrode is conductive, it will continue to operate as if it were clean. Note that eventually it will be necessary to remove the excessive accumulation of residues from the electrode – it is difficult to measure the process with the electrode immersed in its own “microenvironment” of accumulation.
The solid state polymeric reference system Reff allows the sensors to respond instantly to pH changes. This is a very important quality when it requires titration and chemical dosage. The entire wet outer surface of the REFEX reference electrode is electrochemically active, without diffusion/flow potential errors, ensuring a quick response to pH changes and avoiding overdosing and unnecessary waste of expensive chemical reagents. This response feature can result in a significant cost reduction through saving chemical reagents.
Conventional electrodes respond much more slowly due to the time of diffusion of ions through the porous junction. The use of tortuous paths and double junction techniques to prolong the useful life of the electrode only contributes to the slowness of the response, and as the porous junctions become obstructed, the response time decreases further. The slow response inevitably results in the setpoint overtaking and the unnecessary waste of expensive dosage chemicals.
The Reff Electrode is exceptionally resistant to applications that contain toxic substances, even those with components such as cyanide, ammonia and sulfides. This immunity is achieved because the polymeric reference junction is not porous and prevents the material from the process from invading and contaminating the interior of the electrode, causing inevitable drift and failure.
Below, we present some examples of how the REFEX sensors can make a difference.
Sulfides accumulate in wastewater treatment systems due to the anaerobic conditions (without oxygen) in which these facilities operate.
Reff water treatment systems with pH measurement are designed to provide reliable and continuous real-time water quality measurements in treatment systems.
Traditional pH and ORP sensors with porous/open reference junctions, used in processes that contain aggressive and toxic chemicals, often fail due to the poisoning of the reference electrode. The chemicals present in the process spread through the porous junction(s)/open(s) necessary for the operation of this type of sensor and poison the Ag/AgCl electrode within the reference semicell.




Deviations from ideal coagulation conditions (ie, coagulant dosing rates and pH) can seriously affect the performance of treatment in water treatment plants. Coagulants are often pH sensitive and perform better when pH is maintained within a narrow range.
Often, the best performance in turbidity removal and natural organic matter (MON) is achieved in pH ranges from 5 to 6, while at pH > 6, the efficiency in the removal of MON decreases significantly and requires a greater dosage of coagulant. It is evident that the rapid and marked variation in raw water quality represents a major operational challenge to ensure the maintenance of ideal clotting conditions, suitable for the real quality of the raw water.
Reff solid state reference electrodes provide instant response to pH changes. This important measurement quality is vital when the dosage of chemicals is necessary to maintain ideal conditions, as a slow response can lead to both overdosing and underdosing of correction chemicals, often expensive – increasing costs directly with the greater use of these products and indirectly by reducing the efficiency of the coagulation.
The slow response of conventional electrodes in chemical correction control systems leads to an overrun of the setpoints (Fig. 1) and, therefore, a greater consumption of chemicals – chemicals for correction are needed to compensate for overcorrection!
The REFF reference electrodes provide a quick response because its entire wet surface is electrochemically active. This helps to avoid pH oscillations (Fig. 2), resulting in significant chemical savings and greater operational efficiency.
The REFEX system for pH measurement in ultrapure water is designed to provide reliable and continuous real-time water quality measurements in water purification and distribution systems.
Designed to operate as an auxiliary steam system, the system is supplied complete with a flow cell set specially developed to house the measuring electrodes.
Reference pH and glass separators are provided. The robust reference sensor uses a highly stable non-porous polymer interface instead of the traditional porous liquid junction used in all conventional reference electrodes. The non-porous nature of the electrode interface prevents the loss of electrolyte to flow, a serious problem in all conventional probes. Maintaining the reference cell in this way prevents the rapid degradation of the measurement, significantly reduces maintenance costs and eliminates the need for frequent replacement of "consumable" probes.
When necessary, an optional low-cell constant conductivity sensor can be installed in the measurement circuit as an additional parameter.
To complete the package, a multi-parameter analyzer unit is used to provide and transmit real-time information about pH, conductivity and temperature for local SCADA and control systems.