The CSX-64 combines eight individually configurable potentiostat/galvanostat banks for simultaneous electrochemical or impedance measurements, with integrated routing in 64 sensor contacts.

Individually configurable potentiostat/galvanostat interfaces
Integrated routing for larger, ever-changing contact maps.
Here, CV, CA, DPV, LCR-style reading, TEER and more
From direct cabling to adapters and supports specific to each application.

Use the eight individually controlled potentiostats/galvanostat banks to control and measure cells, sensors or regions simultaneously. Critical time changes are captured in a single timeline, while parallel acquisition reduces the time required for larger configurations.
Performs route measurements in 64 contacts and combines parallel measurements with sequential steps. This allows the use of dense arrangements, shared electrodes and variable contact maps without the need to dedicate a complete instrument channel to each position.
Use direct cabling, adapters, edge plates or custom interfaces to connect cells, chips, plates and fastening devices. Keep the instrument side stable when changing sensors, connectors or applications.
Detailed electrical parameters and supported measurement protocols for the basic configuration of the CSX-64.









The CSX-64 becomes especially useful when an application combines simultaneous measurements, many sensor contacts, variable electrode assignments, or a non-standard interface. Its flexible architecture supports the development of sensors, repeatable test workflows, parallel testing, and the development of dedicated measurement systems.
Compare electrode materials, geometries and reading conditions in various prototypes. Reassign contacts and adapt the interface as the project changes, while parallel measurement maintains critical time comparisons on the same schedule.
Perform electrochemical experiments on multiple cells and electrodes. Measure samples with time constraints simultaneously and sequence additional positions via the integrated routing.
Measure the electrical resistance trans-electric (TEER), the integrity of the barrier, the impedance of the cell or the electrochemical responses in wells, chips and sensor regions. Parallel measurement allows for synchronized comparisons, while 64-door routing accommodates custom electrode layouts and shared electrode configurations.
Create and validate complex sensor configurations for on-site diagnostic and service applications. The CSX-64 supports microfluidic interfaces, miniaturized sensor matrices and hybrid measurement techniques, aiming at the development of scalable product concepts.
Build your ideal configuration. Select the number of channels, cable assemblies and accessories required.
64 channels
128 channels
256 channels
more channels
Please specify.
Measuring cable set with 2 mm banana connector
MEC1 harness for 2 mm banana
Measuring cable set with 4 mm banana connector
MEC1 harness for 4 mm banana
Custom cable set
Please specify.
CHIPS CARRIERS
Adapter board with 64 contacts
cable adapter board
CHIP TEST SENSOR
Chip with 24 different sensor structures (IDEs, point electrodes, multielectrode structures)
Custom sliding chip
Please specify.
Base unit
CSX-64
Channel count
—
Cable Sets
—
Accessories
—
Our application engineers will analyze your configuration.
Talk to an ExpertThe CSX-64 combines eight individually controlled potentiostats/galvanostat banks, integrated routing in 64 sensor contacts, and a flexible interface for non-standard sensors. The comparison below shows how it differs from common alternatives — and which requirements usually determine the best choice.
The CSX-64 performs better when parallel control, many physical contacts, flexible electrode assignments and an adaptive sensor interface are required in the same configuration.

Use a discreet wire harness for direct access to the measurement ports. This is the simplest way to use conventional electrodes, separate cells, and early sensor development settings.

Connect arrays, chips, or electrode formats compatible through the Sciospec adapters and expansion boards available. MEArack is an example within a broader interface concept.

Connect proprietary chips, cartridges, plates and test devices through a dedicated adapter or expansion card. Sciospec can evaluate and develop the interface, or your team can design based on the documented SC98 connector system.
Send us a sketch, a pinout diagram or a connector drawing. We will recommend the most appropriate cabling, adapter or connection route.

The CSX-64 offers a flexible professional platform, while the sensor, electrode topology and workflow are still under development. Configure the measurement, connect the application and define what the final system really needs to do.
As the application matures, Sciospec can support the next steps — from a repeatable lab configuration and automated workflow to an application-specific reader or an OEM system.
Use the CSX-64 to determine the required ranges, measurement methods, simultaneous paths and the connection of the sensors.
Add the support, clamping devices, software and automation needed to turn the experiment into a reliable work configuration.
When the requirements are clear, Sciospec will be able to define the scope and develop the dedicated electronics, software, mechanics and application interface.

XOrigin develops flexible microsensor technology for state-of-the-art bioelectronic and diagnostic applications. To go beyond the proof-of-concept configuration existing in its research lab, the company needed something more than a standard LCR instrument. The measurement had to offer exceptional capacitance accuracy, reliably connect to multiple specialized sensors, and maintain their usefulness as the application evolved.
Together, the Xorigin and Sciospec developed the complete measurement solution around this requirement: the flexible CSX-64 as a precision measurement core, a dedicated adapter designed for the sensor and a close development partnership that continues as the product evolves.
The XOrigine sensor required high precision capacitance measurements in a configuration that did not fit into the standard formats and was still under development.
The CSX-64 has been configured for the necessary measurement, providing the required performance and flexibility during sensor development.
Sciospec has developed a sensor-specific adapter in order to create a controlled and practical connection between the Xorigin sensor and the CSX-64.
With this configuration, teams created highly stable measurements accurately in the low femtofarad range on baselines between picofarads and nanofarads, with a temporal resolution of less than 100 ms.
The collaboration did not end with the delivery of the measuring device. Xoritivo and Sciospec continued to jointly develop measurement, interface and system requirements. This gives Xoriti a partner who already understands the sensor, the signal and the application — and creates a viable path from laboratory development to automation, application-specific electronics and integration with OEMs as product requirements mature.
It is possible to perform up to eight simultaneous measurements, usually one per bank. Other combinations of contacts can be measured in subsequent steps.
Send us a sketch, a pinout diagram, or a contact map. We will analyze the measurement task and recommend the simplest and most appropriate configuration — or other instrument, if it is more appropriate.
Select the measurement options, interface and accessories for your application and use the result as a basis for technical analysis and budgeting.
Discuss how measurement, sensor interface and workflow can be developed on an application-specific instrument or an integrated OEM solution.