Single-phase and three-phase test adapter with type 2 plug to test the effectiveness of protective measures on electric recharge stations With the Profitest Master, simulation of fictitiously connected electric vehicles and carrying capacity of cable assemblies according to IEC 61851-1
For vehicle simulation (CP),
states A, B, C, D and E can be simulated according to the IEC 61851. The various states of the vehicle are selected by means of a rotary switch.
About cable simulation (PP):
The various encodings for charging cables with 13, 20, 32 and 63 A can be simulated. It is also possible to simulate the "no cable" state.
The various charging cables are simulated by connecting different resistances between PP and PE with the help of a rotary switch. The following values are possible according to IEC 61851:
1 PRO-TYP II TEST ADAPTER
1 Define operating instructions