608 LN2 Automatic Reload FTIR / Electronic Microscopy FTIR Detector (SEM, has, FIB, Cryo-EM)
Microdosing System LN2 Nº 608
Automatic FTIR Detector LN2 / Electron microscopy (SEM, FIB, Crio-EM) 
The microdosing system #608 LN2 is a universal and automatic liquid nitrogen filling solution designed for a wide range of laboratory applications. Originally designed for the refueling of FTIR detectors, the system is now widely adopted for safe, autonomous and accurate LN2 supply for dewars that serve:
- FTIR detectors (MCT, FPA)
- Microscopes Scanning Electronics (SEM)
- Transmission Electronic Microscopes (MET)
- Focused Ion Beam Systems (FIB)
- Cryoelectronic Microscopes (Crio-EM)
- Other Small Laboratory Instruments LN2 cooled
Adapters are tailor-made for seamless integration with leading brands and custom configurations
Main features of the LN2 automatic filling system:
- Universal compatibility:
custom adapters for Bruker, Netzsch, Shimadzu, Thermo Fisher, Perkin Elmer, Agilent, Horiba, Mettler Toledo, JEOL, FEI, Zeiss, Hitachi, Thermo Fisher Scientific and much more. - Plug-and-Play operation:
Easy setup with most detectors and Dewars; Does not require special tools. - Smooth and precise filling:
adjustable microdosing of a few drops up to 0.5 L/min, ideal for sensitive detectors and cryogenic stages. - Scheduled and on-demand reloads:
schedule refills at preset intervals or manually/externally trigger to avoid stopping measurements. - Safe and clean:
operator without contact with the LN2; Low pressure operation (<300 mbar) for maximum safety in the laboratory. - Without ice formation:
the pressure is generated by the internal vaporization of the LN2, preventing the entry of air and the accumulation of ice. - Silent and without vibration:
no solenoid valves or noisy pumps — ideal for sensitive instruments. - Night and autonomous operation:
supports long runs of measurements and continuous cooling of the instrument.
Specifications and Options
LN2 Microdosage Systems
Liquid nitrogen (LN2) is used as a cooling medium and is taken from a low-pressure storage container (max. 300 mbar) and delivered (pumped) through a fill line for application in a microdosed shape.
The LN2 microdosage system is designed to overcome the disadvantages of the LN2 under pressure, in which a solenoid valve is used to turn on/off the supply. You can compare the system to a faucet, but instead of providing water, it provides liquid nitrogen gently, with an adjustable flow, possible to regulate from a few drops, up to 1 liter/minute. Our pump can pump LN2 up to 4 meters above the pump itself.
The Dewar Reservoir can be easily installed near your workplace. When you need a small amount of LN2, the system will be ready to supply the liquid by pressing only the pump head. By pressing the pump head, the system begins to generate a small overpressure, forcing the liquid to gently rise to the filling line and fall into its small container of Dewar or another small container of LN2. After releasing the pressure on the pump head, the system automatically shuts off and the flow stops.
Operating Principle

The pressure above the liquid level within the Dewar is generated by heating a small amount of liquid at the bottom of the Dewar. With only 100 mBar of overpressure, the liquid rises smoothly through the lifting tube and descends to the filling hose. As we evaporate a little LN2 to generate pressure, there is no addition of ice inside the Dewar, as happens in manual systems that use ambient air.
When LN2 is required, a small overpressure is generated by a small heating element in the LN2, and the liquid flows out of the system like tap water, no spillage, noise, vibrations, etc.
Software

This software works on Windows 98 – 2000 – ME – NT – Vista – W7 – Windows 10 – Windows 11.
Each system #608 includes a Datalogger software function. This recorder allows you to document any parameter value over time and preset the time interval for your detector.
608 Series Technical Specifications
| Flow rate | Up to 0.5 liter per minute | ||
| Average working pressure | 100 mbar (adjustable to the software provided) | ||
| Maximum working pressure | 300 mBar | ||
| Reaction time | +/- 1 minute to cool the fill line (with 1.6 meters filling line) | ||
| Power connection | 115 V / 230 V AC with power supply supplied or 12-24V AC/DC | ||
| Consumption power | average of 10 watts, during pumping 50 watts | ||
| Model | 608-100-035 | 608-100-050 | 608-100- 100 |
| Storage container volume | 35 liters | 50 liters | 100 liters |
| External dimensions (diameter) | 460 mm | 460 mm | 500 mm |
| Dimensions of height | 802 mm | 917 mm | 1235 mm |
| Weight (empty, full) | 15 / 42 kg | 17 / 59 kg | 34 / 115 kg |
| Static wait time (days) | 112 dias | 122 dias | 164 dias |
| Standard fill line | 1.6 m line length, 6.25 mm outside diameter, 4 mm inner diameter, FEB Teflon tube, with Armaflex foam insulation 32 mm outside diameter | ||
| The system includes | Dewar, pump, 1.6 m filling line, phase separator, filling tubes, power supply, cables, 1 level sensor, PC software. | ||
| Work modes | Automatic filling control with timer (1 sensor) | ||
| External control | 5 volt signals for ON/OFF and RS232 signals for ON/OFF | ||
| PC Software | Monitoring software for monitoring Pumps and Data Record | ||
| Alarms/Warnings
acoustic/Visual/mechanical |
Dewar empty, 4-liter Dewar LN2 remaining, broken sensor(s), frozen alarm, mechanical protection against overpressure. | ||
| Options | Custom adapter with sensor for all brands of detectors tailor-made adapter for fixing sensor(s) in the 5-wheel transport cart application (10 cm high)
Pump holder (when the Dewar is replenished) |
||
| DeWar Cart Option | 900-400-000 | 900-400-000 | 900-400-000 |
| Floor Support Option | 900-400-100 | 900-400-100 | 900-400-100 |
| Tailor-made Adapter | 600-400-000 | 600-400-000 | 600-400-000 |
608 Series FTIR Adapters

As standard, we have adapters for Bruker, Netzsch, Shimadzu, Thermo Fisher systems, Perkin Elmer, Agilent, Horiba, Mettler TOLEDO, but we also have adapters available for other detectors or make a custom design.

Most of this system is used in laboratories and research centers where FTIR measurements are made and where a safe and autonomous recharge of LN2 is required.
608 Series Applications:
– Autonomous automatic reloading of LN2 for FTIR detectors
– Laser detector reload
– Night measurements
– Automatic measurement sequences
– Automatic filling of other small LN2 reservoirs, with very low LN2 flow